Ex-industries

Intrinsically safe isolated barriers


• Three port galvanic isolation.
• Ultra slim 4 channels 22,5 mm wide DIN rail mounting modules.
• Configure using DIP switch for easy field set up.
• Microprocessor models configurable using software or pocket portable configurator.
• Line Fault alarm detects open or short circuit of field cables.
• LED indication for power, signal status and line fault conditions.
• Plug-in screw terminal blocks to secure termination up to 2,5 mm2.
• Relay contacts rated for 2 amp. to directly switch high loads.
• Models accept DC power supply over a wide range.

Ex protection: II3(1)G Ex nA [ia GA] IIC T4 Gc, Ex [ia Da] IIIC
Ambient temperature : -20°C ÷ +60°C
EC Type certificat: DMT 01 ATEX E 042 X

Download the catalogue
 

Filter

Product

D1010S

Intrinsically safe analog input 0/4-20mA repeater-converter, Hart-Smart compatibel, 1 Channel, SIL 3
Input: 0-20mA ǀ 4-20mA
Output: 0/4-20mA ǀ 0/1-5V ǀ 0/2-10V

D1010D

Intrinsically safe analog input 0/4-20mA repeater-converter or signal duplicator, Hart-Smart compatibel, 2 Channels, SIL 3
Input: 0-20mA ǀ 4-20mA
Output: 0/4-20mA ǀ 0/1-5V ǀ 0/2-10V

D1010S/B

Intrinsically safe analog input 0/4-20mA repeater-converter, Hart-Smart compatibel, 1 Channel, Power bus enclosure, SIL 3
Input: 0-20mA ǀ 4-20mA
Output: 0/4-20mA ǀ 0/1-5V ǀ 0/2-10V

D1010D/B

Intrinsically safe analog input 0/4-20mA repeater-converter or signal duplicator, Hart-Smart compatibel, 2 Channels, Power bus enclosure, SIL 3
Input: 0-20mA ǀ 4-20mA
Output: 0/4-20mA ǀ 0/1-5V ǀ 0/2-10V

D1010S-046

Intrinsically safe analog input 0/4-20mA repeater-converter, Hart-Smart compatibel, 1 Channel, SIL 3
Input: 0-20mA ǀ 4-20mA
Output: 0/4-20mA ǀ 0/1-5V ǀ 0/2-10V

D1010D-046

Intrinsically safe analog input 0/4-20mA repeater-converter, Hart-Smart compatibel, 2 Channels, SIL 3
Input: 0-20mA ǀ 4-20mA
Output: 0/4-20mA ǀ 0/1-5V ǀ 0/2-10V

D1010S-046/B

Intrinsically safe analog input 0/4-20mA repeater-converter, Hart-Smart compatibel, 1 Channel, Power bus enclosure, SIL 3
Input: 0-20mA ǀ 4-20mA
Output: 0/4-20mA ǀ 0/1-5V ǀ 0/2-10V

D1010D-046/B

Intrinsically safe analog input 0/4-20mA repeater-converter, Hart-Smart compatibel, 2 Channels, Power bus enclosure, SIL 3
Input: 0-20mA ǀ 4-20mA
Output: 0/4-20mA ǀ 0/1-5V ǀ 0/2-10V

D1012Q

Intrinsically safe analog input 4-20mA repeater-converter, 4 Channels
Input: 4-20mA
Output: 4-20mA

D1014S

Intrinsically safe analog input high integrity 4-20 mA repeater-converter, Hart compatibel, 1 Channel, SIL 3
Input: 4-20mA
Output: 4-20mA ǀ 1-5V ǀ 2-10V

D1014D

Intrinsically safe analog input high integrity 4-20 mA repeater-converter, Hart compatibel, 2 Channels, SIL 3
Input: 4-20mA
Output: 4-20mA ǀ 1-5V ǀ 2-10V

D1014S/B

Intrinsically safe analog input high integrity 4-20 mA repeater-converter, Hart compatibel, 1 Channel, Power bus enclosure, SIL 3
Input: 4-20mA
Output: 4-20mA ǀ 1-5V ǀ 2-10V

D1014D/B

Intrinsically safe analog input high integrity 4-20 mA repeater-converter, Hart compatibel, 2 Channels, Power bus enclosure, SIL 3
Input: 4-20mA
Output: 4-20mA ǀ 1-5V ǀ 2-10V

D1054S

Intrinsically safe analog input 0/4-20 mA repeater-converter with trip amplifier, Hart-Smart compatibel, 1 Channel, SIL 2
Input: 0-20mA ǀ 4-20mA
Output: 0-20mA ǀ 4-20mA ǀ 0/1-5V ǀ 0/2-10V ǀ High-Low trip amplifier

D1054S/B

Intrinsically safe analog input 0/4-20 mA repeater-converter with trip amplifier, Hart-Smart compatibel, 1 Channel, Power bus enclosure, SIL 2
Input: 0-20mA ǀ 4-20mA
Output: 0-20mA ǀ 4-20mA ǀ 0/1-5V ǀ 0/2-10V ǀ High-Low trip amplifier

D1020S

Intrinsically safe Analoge uitgang 0/4-20 mA transmitter, Hart-Smart compatibel, 1 Channel, SIL 2
Input: 0-20mA ǀ 4-20mA
Output: 0-20mA ǀ 4-20mA

D1020D

Intrinsically safe Analoge uitgang 0/4-20 mA transmitter, Hart-Smart compatibel, 2 Channels, SIL 2
Input: 0-20mA ǀ 4-20mA
Output: 0-20mA ǀ 4-20mA

D1020S/B

Intrinsically safe Analoge uitgang 0/4-20 mA transmitter, Hart-Smart compatibel, 1 Channel, Power bus enclosure, SIL 2
Input: 0-20mA ǀ 4-20mA
Output: 0-20mA ǀ 4-20mA

D1020D/B

Intrinsically safe Analoge uitgang 0/4-20 mA transmitter, Hart-Smart compatibel, 2 Channels, Power bus enclosure, SIL 2
Input: 0-20mA ǀ 4-20mA
Output: 0-20mA ǀ 4-20mA

D1021S

Intrinsically safe Analoge uitgang 4-20mA transmitter with fault detection, Hart-Smart compatibel, 1 Channel, SIL 2
Input: 4-20mA
Output: 4-20mA ǀ Fault ouput

D1021S/B

Intrinsically safe Analoge uitgang 4-20mA transmitter with fault detection, Hart-Smart compatibel, 1 Channel, Power bus enclosure, SIL 2
Input: 4-20mA
Output: 4-20mA ǀ Fault ouput

D1030S

Intrinsically safe digital input switch or NAMUR device repeater, 1 Channel, Relay output
Input: Namur device ǀ Voltage free contact
Output: Relay output ǀ Fault output

D1030D

Intrinsically safe digital input switch or NAMUR device repeater, 2 Channels, Relay output
Input: Namur device ǀ Voltage free contact
Output: Relay output

D1030S/B

Intrinsically safe digital input switch or NAMUR device repeater, 1 Channel, Relay output, Power bus enclosure
Input: Namur device ǀ Voltage free contact
Output: Relay output ǀ Fault output

D1030D/B

Intrinsically safe digital input switch or NAMUR device repeater, 2 Channels, Relay output, Power bus enclosure
Input: Namur device ǀ Voltage free contact
Output: Relay output